Main Functions

    • Resistance graphite furnace (He/Ar) process gas regulation function
    • Resistance graphite furnace circulating cooling water adjustment and return water temperature display function
    • Precast rod local melting drawing function
    • Temperature adjustment function of wire drawing furnace
    • Horizontal and X, Y resistance furnace position adjustment function 
    • To achieve the drawing furnace vacuum, vacuum degree of at least -0.8mbar function
    • When the water and gas are under pressure, it has the protection function of  cutting off gas and water

Product Specifications

Indicator long hot zone short hot zone
Furnace body height 400±10mm 200±10mm
Preform diameter 10 - 50mm
Operating temperature 1100℃ ~ 2500℃
Temperature control accuracy ±0.5℃
Liner inner diameter 107±1mm and 82±1mm 38±1mm and 61±1mm
Heating body length 120mm and 90mm 35mm and 55mm
Power 45KW
He gas flow range 0 ~ 50 SLM
Ar gas flow range 0 ~ 50 SLM
Reference range of cooling water flow 0 ~ 100 L/Min
Gas pressure reference range 6 ~ 12 Bar
Cooling water pressure range 0 ~ 5 Bar